Clear Connect Enabled – Lutron's patented RF Technology uses a quiet band, essentially free of interference ensuring reliable communication between system devices
Vacancy Sensing – Automatically turn off the lights and when integrated with RMS turn off electronic appliances off when a person leaves the space
Occupancy Sensing – Turn lights on when a person enters a room and when integrated with RMS automatically turns on electronic appliances in the room
Simple Web Configuration – Browse to the NetLinx® Clear Connect Gateway URL to quickly setup the Clear Connect Switch
OVERVIEW The Lutron Clear Connect CCD-RS-277-WH is a 277V Accessory Switch that is used with CCD-8S-WH Clear Connect 120/277V Switches. The Switch when added to a Clear Connect System provides light control to virtually any location, without pulling wires.
Clear Connect Enabled – Lutron's patented RF Technology uses a quiet band, essentially free of interference ensuring reliable communication between system devices
Vacancy Sensing – Automatically turn off the lights and when integrated with RMS turn off electronic appliances off when a person leaves the space
Occupancy Sensing – Turn lights on when a person enters a room and when integrated with RMS automatically turns on electronic appliances in the room
Simple Web Configuration – Browse to the NetLinx® Clear Connect Gateway URL to quickly setup the Clear Connect Switch
Warranty - Yes
Operating Temperature (Maximum):
104 F
Operating Temperature (Minimum):
32 F
Certifications:
UL, FCC
AC Voltage:
277 Volts
Warranty (Length/Type):
3 Years Limited
Wattage (max capacity):
0.20 Watt
Power:
Power: Power: 277 V 50 / 60 Hz
Typical Power Consumption
Dimmer / Switch: 0.2 W
Test conditions: load is off and nightlight mode is enabled
Remote Dimmer / Switch: 0 W
Test conditions: load is off
Surge Protection: To withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits
Power Failure: Power failure memory: should power be interrupted, the Clear Connect Gateway will return to its previous state when power is restored
Environmental:
Operating Humidity: 0 to 90%, Non-condensing
Indoor use only
ESD Protection:
To withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2
COMMUNICATIONS:
Dimmers and switches communicate with the system through Radio Frequency (RF) and must be located within 30 ft (9 m) of a repeater
Remote dimmers / switches are not required to be within a specific range of a repeater. System devices operate on frequencies between 431.0 MHz and 437.0 MHz
Installation:
Mounting Requires a U.S. wallbox. 3 . in (89 mm) deep recommended, 2 . in (57 mm) deep minimum